After a fresh install of Cisco UCS, release 2.0: The FCoE VLAN for the default VSAN uses VLAN
4048 by default. The FCoE storage port native VLAN uses VLAN 4049.
Step 6
Click Save Changes.
Enabling Fibre Channel Uplink Trunking
If the fabric interconnects are configured for Fibre Channel end-host mode, enabling Fibre Channel uplink
trunking renders all VSANs with an ID in the range from 3840 to 4079 non-operational.
Note
Procedure
Step 1
In the Navigation pane, click the SAN tab.
Step 2
On the SAN tab, expand SAN > SAN Cloud.
Step 3
Click the node for the fabric where you want to enable FC uplink trunking.
Step 4
In the Work pane, click the General tab.
Step 5
In the Actions area, click Enable FC Uplink Trunking.
Step 6
If the Cisco UCS Manager GUI displays a confirmation dialog box, click Yes.
Disabling Fibre Channel Uplink Trunking
Procedure
Step 1
In the Navigation pane, click the SAN tab.
Step 2
On the SAN tab, expand SAN > SAN Cloud.
Step 3
Click the node for the fabric where you want to disable Fibre Channel uplink trunking.
Step 4
In the Work pane, click the General tab.
Step 5
In the Actions area, click Disable FC Uplink Trunking.
Step 6
If the Cisco UCS Manager GUI displays a confirmation dialog box, click Yes.
Cisco UCS Manager GUI Configuration Guide, Release 2.0